Specification
WarmcelŽ 100 for lofts and floors conforms to the requirements of
British Standard BS5803, 1985 “Thermal Insulation for Use in Pitched
Roof Spaces in Dwellings”, Part 3 “Specification for cellulose Fibre
Thermal Insulation for Application by Blowing” and the fire performance
requirements of BS 5803,Part 4:1985 “Methods for Determining
Flammability and Resistance to Smouldering”.
Certification
Registered by BSI Quality Assurance as a Firm of Assessed Capability to
manufacture cellulose fibre thermal insulation in accordance with BS EN
ISO 9003 1994; licence no. FM372. The assessment is on-going with random
unannounced visits by the BSI Quality Assurance Inspectorate.
Approval
• Satisfies the requirements of the Building Regulations B1 (fitness of
materials).
• Department of the Environment, Transport and Regions (DETR). Accepted
for use under the Home Energy Efficiency Scheme and for “Minor Works
Assistance Grants”.
• New Housing - Accepted by NHBC, Zurich, Foundation 15 and HAPM for use
in lofts and timber frame walls.
Product Type
The insulation is composed of cellulose fibres derived from waste
newsprint treated with fire retardant and biocidal additives.
Installation
Lofts
It is recommended that the insulation is installed according to the
requirements laid down in BS 5803,Part 5:1985 - “Specification for
Installation of Man Made Mineral Fibre and cellulose Fibre Insulation”,
with additional requirements as set out in the Company's Installation
Manual.
Product Properties
Test methods referred to in this section are described fully in BS
5803:1985, Parts 3 & 4.
Corrosion
The insulation does not contain water-soluble substances likely to
accelerate the corrosion of metallic surfaces with which it comes into
contact.
Settlement in lofts - at high humidity
When tested under conditions of high humidity the material settles by
2.2% against an allowable maximum 5%.
Settlement in lofts - under vibration
When tested under conditions of accelerated vibration the material
settled by 5.3% this should be allowed for when calculating installed
thicknesses.
Electrical wiring
WarmcelŽ has no deleterious effect on PVC covered electrical wiring.
Vapour resistivity
9.3 MNs/gm, tested by wet cup method.
Thermal Insulation
For calculating the thermal performance for compliance with building
regulations or other statutory regulations the material has a thermal
conductivity (K value) of 0.035 W/mK in horizontal loft spaces when
measured by a guarded hot plate test to BS 874:1973 - “Methods of
Determining Thermal Insulating Properties”.
U-Values
All U-values are calculated to allow for thermal bridging using the
proportional area method.
Assumed Roof Construction
10mm tiles on battens, sarking felt, loft space, 100x38mm joists on
600mm centres with WarmcelŽ over & between, 10mm plasterboard.
|
Settled U-Value
|
Thickness mm W/m2K
|
|
93mm
|
0.35
|
|
109mm
|
0.30
|
|
132mm
|
0.25
|
|
164mm
|
0.20
|
|
217mm
|
0.15
|
Fire Performance
WarmcelŽ meets the requirements of the following British Standard BS5803
tests.
Flammability Resistance Test
A specimen of conditioned insulation is inserted in a tray having a
plasterboard base and wooden sides representing a typical configuration
of joists and ceiling forming the base of a loft. A small wooden crib is
placed on the surface and inflammable liquid is added and then ignited.
Observations are made of the occurrence and duration of flaming and
smouldering of the insulation, outside the area covered by the crib, and
the extent of spread of the combustion zone.
Smouldering Resistance Test
A specimen of conditioned insulation is inserted in a tray similar to
that described in 6.3.1. containing a pre-heated metal cylinder.
Observations are made of the duration of any flaming and smouldering of
the insulation and of the extent of spread of the combustion zone.
Packaging
The packs are marked with the following information:
• This product conforms to BS5803:1985,Part 3.
• The product brand name e.g. WarmcelŽ
• Product Description - Blown cellulose Fibre Insulation.
• Material accidentally soaked should be removed and replaced.
• Pack weight - 8.0kg
The following relates to horizontal loft spaces only:
• Maximum percentage settlement 5.3%.
• Average density installed 35kg/m3, settled 34kg/m3.
• Thermal conductivity 0.035W/mK at settled density.
• Health and safety. WarmcelŽ is non-irritant and no special precautions
are required. A disposable facemask should be worn when working in
confined dusty areas. When considering COSHH assessments involving the
use of WarmcelŽ the material should be classed as non-hazardous.
To download a printer friendly PDF of this datasheet click here